Dual Membrane Industrial Reverse Osmosis Units

 

Standard Features

  • 2 NSF Certified Membranes on LP-5000
  • Stainless Steel Membrane Housing
  • Gould’s Multi Stage SS Centrifugal Pump
  • TDS Monitor for Product and Feed
  • Low Pressure Safety Cut Off
  • Product and Drain Flow Meters
  • Stainless Steel Drain Valve
  • 2″ x 20″ Sediment Pre Filter
  • Inlet Solenoid Valve
  • SS Operating Pressure Gauge
  • Comprehensive Warranty
  • Easy to Install and Maintain
  • Aluminum Frame

Low Pressure Units are based on 500 ppm properly pre-treated water at 115 psig operating pressure and 77degree water.

High Pressure Units are based on 2000 ppm properly pre-treated water at 225 psig operating pressure and 77degree water.

[pi_enquiry_button]
Facebook
Twitter
LinkedIn

Description

Optional Features

  • Auto Flush
  • Waste Recycle
  • Pre Filter Gauge
  • Control Panel
  • Crating
  • Powder Coating (Custom Colors)

Unit Options & Specifications

Unit LP-5000 HP-4400
Membrane size
Part #
2 4×40 low pressure
PM-4040-BLF
2 4×40 high pressure
PM-4040-BE
GPD 5000 4400
Production GPM 3.95 3
Rejection GPM 3.95 7
Total GPM 7.91 10
Recovery 50.00% 30.00%
Operating PSI 115 225
Motor Horse Power 0.5 1.5
Volts 115/230 115/230
Amps 10.8/5.4 21.4/10.7
Connection Feed 3/4” 3/4”
Connection Product 3/4” 1/2”
Pump Model 7GBS05FS 10GBS15FS
Pre-Filter Size 2×20 2×20
Dimensions WxDxH 22x23x65 22x23x65
Approximate Unit Weight 130 lbs. 130 lbs.
Print Friendly, PDF & Email